Sites and site agents
Sites are boot and failure domains. A bcd site agent in each one runs proxy DHCP, iPXE, the image cache and BMC access, with one active boot server per site.
A is a boot and failure domain: a room, a cage or a lab whose machines share a provisioning network and a BMC network. Everything the control plane does to a machine's hardware (power, boot device, network boot, image streaming) goes through a on that site, because the control plane never dials into a site. Pools, nodes and join tokens all belong to exactly one site.
Sites
A site has an owner, a kind and a region:
| Kind | Owner | Created under | Use it for |
|---|---|---|---|
shared | the root (platform) tenant | compute-fleet/global | platform hardware shared through offerings |
dedicated | the root tenant | compute-fleet/global | platform hardware set aside for one customer |
custom | the tenant | compute-tenant/{t} | a tenant's own hardware (bring your own) |
Every sites.* mutation is decided as compute:sites:manage. Creating a shared or dedicated
site with a tenantId other than the root tenant is INVALID_INPUT.
const site = await compute.api.sites.create(credential, {
tenantId: 'root',
kind: 'shared',
region: 'eu-central-1', // a region label
iamRegion: 'eu-central', // optional: the IAM region name, when it differs
idempotencyKey: 'site-fsn1',
});
// { id: 'site_…', ownerTenantId: 'root', kind: 'shared', region: 'eu-central-1', iamRegion: 'eu-central', version: 1 }The id derives from the tenant, the caller and the idempotency key, so a retry returns the same site
and a different request under the same key is CONFLICT. The site's region, iamRegion and
kind are the attributes IAM conditions see on compute-site.
sites.update(v0.2) changesregionandiamRegion, or clearsiamRegionwithclearIamRegion: true. Pass theversionyou read to getCONFLICTinstead of a lost update.sites.delete(v0.2) refuses withINVALID_STATEwhile the site still has live pools or nodes. Otherwise it revokes every join token of the site (site tokens included), expires its open join requests, drops its boot lease, and removes the row, or tombstones it when anything ever referenced it. Deleting a tombstoned site again answersdeleted: false.
The site agent
A site agent is bcd running in site mode on a machine next to the fleet, one or two per site. To
the control plane it is a node like any other: a nodes row with role = 'site', no pool, a
site certificate and a session through the gateway. It runs the site's commands:
| Duty | When | In bcd site today |
|---|---|---|
| Proxy DHCP, so booting machines find the iPXE binary without replacing your DHCP server | only while holding the boot lease | yes, with [boot] proxy_dhcp |
| TFTP and iPXE scripts, one per machine being booted | only while holding the boot lease | yes: read-only TFTP for the iPXE builds, scripts over plain HTTP |
| Vouching for ramdisks that PXE-booted from it (signed discovery assertions) | only while holding the boot lease | yes |
| An image cache that ramdisks stream from | always (a boot's grant only while holding the boot lease) | yes, by digest under a grant (GET /cache/t/<grant>/<sha256>, b7ed8a2) |
| BMC access (Redfish, IPMI, vendor drivers) on the management network | always | Redfish built in; IPMI power, boot device and inspection through the hosted bcx-ipmi plugin (51806ab, 7818f19), which daemon install-script --install-plugins bcx-ipmi installs from the release (adf2ae9); no vendor driver |
The command kinds it accepts are role-restricted to site: bmc.query, bmc.boot, bmc.power,
bmc.rotate, bmc.firmware, bmc.storage, boot.prepareRamdisk, boot.cleanUp and site.httpProxy, plus
the shared inventory.refresh, logs.collect and node.reboot. Their payloads are messages of
bettercompute.site.v1, which stays a draft package until v0.2 closes. Every bmc.* kind but bmc.query, and
site.httpProxy since 0d42de8, is destructive, so under the v1.0 quorum it runs only in an approved batch;
site.httpProxy also never reaches a BMC (the agent refuses the BMC hosts it drives, any /redfish path and its
local [site] bmc_networks), and reaches only the addresses of the agentless machine it names (SiteSpec.proxy_targets,
which metal fills from inspection; a2a853d, 8391d74). See
BMC drivers and credentials and the
command kinds reference.
The agent's desired state is the site section of its NodeSpec (SiteSpec): the boot lease state (below) and,
since v0.2, cacheImages, the verified catalog images its cache pre-warms (url, sha256, format). The
provision module fills that list: every live pool of the agent's site can name images in policy.prewarmImages
(name@version refs, resolved in the pool owner's catalog), and only images that still verify (signed, signer not
revoked, row untampered) are listed, deduplicated by URL. The agent pulls each one and re-verifies its digest before
serving it. images.register and images.promote recompute the specs of the site agents whose pools name the ref,
and so does pools.update when prewarmImages changes. Modules contribute site fields independently, because
the section merges field by field (see NodeSpec sections).
Enroll site agents with site tokens
A site agent joins with a site token: a join token of role site, bound to one site and no pool.
siteTokens.create is decided as compute:sites:manage on
compute-site/{siteId}, and only the site's owner can mint one.
const minted = await compute.api.siteTokens.create(credential, {
tenantId: 'root',
siteId: site.id,
ttlSeconds: 3600, // 60 to 86 400
maxUses: 2, // how many agents may enroll with it: 1 (default) to 16
idempotencyKey: 'fsn1-site-agents',
});
// { id: 'jt_…', siteId, role: 'site', usesLeft: 2, expiresAt, token: 'bcjt_<id>.<secret>' }- The bearer (
bcjt_<id>.<secret>) is in the answer that created the token and nowhere else: only its hash is stored, and a replay of the same request omits it. The same key for another site isCONFLICT. - A deleted site is
INVALID_STATE; a site the tenant does not own isNOT_FOUND. siteTokens.revoketakestenantId,siteIdandtokenId. It revokes only site tokens: a node join token isNOT_FOUNDthere.- Both publish security events:
security.site-token.createdandsecurity.site-token.revoked.
From the command line (573b0b0), where --out writes the one-time token to a new 0600 file instead of printing it
and revoke refuses a pasted token (anything with a .), so the secret is never sent as an id:
better-compute sites create --tenant root --kind shared --region eu-central-1 --iam-region eu-central --key site-fsn1
better-compute site-tokens create --tenant root --site site_01k5w… --ttl 3600 --max-uses 2 --out ./site-token
better-compute site-tokens revoke jt_01k5w… --tenant root --site site_01k5w…site-tokens create --ttl is in seconds (60 to 86,400).
The agent joins through the same Join RPC as any daemon (see joining nodes),
and JoinService issues it a 24-hour certificate with role site. With bcd that is
BCD_JOIN_TOKEN=bcjt_... bcd join --role site, then bcd site; see
installing bcd.
One active boot server per site
Two agents answering DHCP for the same machine would race, and a stale agent vouching for a ramdisk
would be a way in. So exactly one agent per site is the boot server: the holder of the lease
site:<siteId>:boot.
- The lease has a 15-second TTL and a fencing epoch that grows on every change of holder.
- The SiteBoot controller renews it while its holder is a connected site agent. The holder learns
that it is active, and at which epoch, from the
sitesection of its NodeSpec (BootLeaseState). - A holder that loses its session keeps the lease until it expires and self-fences after the TTL: it stops answering proxy DHCP, iPXE and discovery. Only then is the first connected standby (by node id) promoted, under a new epoch. A live lease never changes hands, so two agents can never both believe they are active at the same epoch.
- When no agent is left, the lease is released and the epoch still moves on.
- Every discovery assertion carries the epoch the agent held, and the control plane refuses an epoch that is not the lease's current one.
The lease logic is the server's SiteBoot controller (tickSiteBoot). betterCompute() registers it as the built-in
site-boot module: a singleton reconciler whose tick key runs every 5 seconds in the controllers role.
A failover does not restart a machine that was already booting. BMC operations are reroutable between a site's
agents: a power cycle the dead agent already ran is reused, not sent again, and one it never received is moved to
the new agent. Boot entries stay per agent, so the new lease holder gets its own entry (and its own single-use
discovery token) and serves the waiting machine. tests/metal-site-failover.test.ts kills the active agent right
after it power-cycled a machine: the standby is promoted when the dead agent's lease runs out, never earlier, the
machine boots from it within 30 seconds, the deploy completes, and the boot step's BMC commands ran once. With both
agents down the boot waits, and the first agent back serves it.
Where site steps go
siteAgentFor(nodeId) picks the agent for a machine's site steps: a connected site agent of the
machine's own site, the boot-lease holder first, otherwise the first connected agent by id. A machine's
site steps never go to another site's agent. When no agent is connected, a relaying step waits and
retries until its timeout, and a step that runs on site directly fails with NO_SITE_AGENT at its
deadline. PLAN.md also routes BMC and image-cache work to any agent that advertises the driver; that
is not implemented.
Booting a machine into the ramdisk
Metal never lets a machine boot something it did not prepare. Before each network boot, the
metal.ensureRamdisk step sets a one-time PXE boot through the BMC, sends the site agent one boot
entry per known PXE MAC, and power-cycles the machine:
- Each entry (
ProxyDhcpEntry) names the MAC, the SMBIOS product UUID when known, the boot architecture (BIOS,X86_64_EFIorARM64_EFI, from the node'sarchanduefi), the workflow and anotAftertwo hours out. - Each entry carries a fresh single-use
discoveryjoin token bound to that MAC (expect.mac), valid for 900 seconds. The token is stored in the secret store and the entry carries only its reference; the site agent fetches the bearer with a SecretRequest for that workflow step and renders it into that MAC's iPXE script. No command body ever holds the token. - A token is minted only when its entry's command is first sent, not on every poll, and the cleanup
step
boot.cleanUpremoves the entries and deletes the stored tokens. - A machine with no known MAC fails with
INVALID_STATE: inspect it out of band first. The one exception (3d26428) is a machine enrolled with a usableproductUuidand no MACs:metal.ensureRamdiskPXE-boots it once with no entry so a site agent lists it, and goes on once the MAC discovery proposes is confirmed withmetal.confirmMac(8de6e2f), or bound at once on a pool that trusts its provisioning network.
The boot server in bcd site
bcd site keeps the boot entries it receives in data_dir/boot-entries.json, keyed by MAC, so a restart keeps
answering; boot.cleanUp drops a workflow's entries (or the listed MACs), and lapsed entries are dropped on their
own. With a [boot] section in its config (see installing bcd) it serves them
in three stages:
- Proxy DHCP (UDP 67 and 4011,
proxy_dhcp = true) answersPXEClientandHTTPClientrequests beside your DHCP server and never hands out an address. It reads the MAC, the client architecture (option 93) and whether the client is iPXE already. Firmware gets the iPXE build for its architecture from TFTP atserver_ip:undionly.kpxefor BIOS,ipxe.efifor x86-64 UEFI,ipxe-arm64.efifor arm64 UEFI. UEFI HTTP boot clients get the same build as a URL,<url>/boot/files/<file>. iPXE itself gets<url>/boot/chain.ipxe, which chains to/boot/ipxewith its MAC, SMBIOS UUID and IP. - TFTP (
tftp,tftp_root) is read-only, octet mode, with block size and transfer size negotiation, and serves nothing outside its root. You supply the iPXE builds. Since 4d8b493 it runs at most 64 transfers at once and 4 per source address; a request beyond either bound is dropped unanswered (answering would take a socket too), and the firmware retries. GET /boot/ipxerenders the machine's script: the site's ramdiskkernelandinitrd, and on the kernel command line thebc.*boot parametersbcd ramdiskjoins with (the gateway, pins and join key, the machine's discovery token and a signed assertion, andbc.cachewhenurlis set), thencmdline.
Proxy DHCP answers, and /boot/ipxe renders a script, only when both hold:
- the MAC has a live boot entry; an unknown machine gets no proxy DHCP answer and a 404 script that exits, so it falls through to its next boot device, and is listed as discovered (see discovering new machines);
- the agent is the active boot server: its
sitesection says it holds the lease at a non-zero epoch, and it has heard from the gateway within the lease TTL (15 seconds when the section gives none). A partitioned agent fences itself this way; its/boot/ipxeanswers 503 with a script that waits 10 seconds and reboots.
The discovery token is fetched with a SecretRequest bound to the entry's workflow the first time the machine asks
for its script and reused if it asks again; while it is not available the script waits and retries. Each script
carries a fresh DiscoveryAssertion (the site, this agent's node id, the lease epoch, the MAC, the IP from the query
or the connection, the product UUID from the query or the entry, the workflow, issued_at in server time, and a
not_after at most 15 minutes out and never past the entry's), signed by the agent's node key under purpose
discovery-assertion.
Sanboot of a cached ISO (0056e1e, e763001). For a BMC without virtual media, such as ipmi, a boot entry may
carry ProxyDhcpEntry.sanboot_sha256 instead of a ramdisk boot: /boot/ipxe then answers
sanboot --no-describe <url>/cache/t/<grant>/<sha256>, and iPXE reads the ISO from the image cache with HTTP range
requests. The ISO boots as it is, with no discovery token and no bc.* parameters. The agent serves it only when
the site spec names that digest as an iso cache image and the verified copy is cached. Otherwise the machine waits
(a 503 script that sleeps 30 seconds and chains again, never the ramdisk), and the site section fails naming the
entry. Since 3d26428 metal sets sanboot_sha256: a media.insert step that names a catalog ISO (image) on a
driver without virtual media pins the ISO at the site and, once the site's cache holds it verified, sends a boot
entry for it (see sanboot instead of virtual media).
The image cache is served by the same HTTP server, and since b7ed8a2 only under grants: every cache URL the agent
hands out has the form GET /cache/t/<grant>/<sha256 hex>, with an unguessable 128-bit grant, and any other path,
a plain /cache/<sha256> included, is 404. The cache holds tenants' deploy images, so nothing is served to whoever
asks:
| Grant | Handed out as | Serves | Valid |
|---|---|---|---|
| A boot | The ramdisk's bc.cache in its iPXE script, and a sanboot URL | Any cached image (bc.cache; the ramdisk checks the digest its command names) or that one ISO (sanboot) | Until the boot entry's not_after (6 hours for an entry without one), and only while the agent holds the boot lease: otherwise 503 |
| A BMC firmware update | The URL the BMC fetches the firmware image from | That one digest | 2 hours |
The agent pulls every cacheImages entry of its site section in the background into
data_dir/cache/<sha256>, and a copy becomes visible only after its bytes match the digest. The site section
stays PROGRESSING while images warm and fails for an image whose bytes do not match. With [boot] cache_max_bytes
set, each pass trims the cache to that budget, least recently used first, and never evicts an image the section
still names (the pools' pre-warm images plus every image a deploy at the site is streaming). A ramdisk booted with
bc.cache tries the cache first for deploy.image and falls back to the image's source URL; the digest is checked
on the stream either way, so a cache can never substitute an image. The boot server caps request headers at 8 KiB
(0442561), since any machine on the segment can reach it.
The discovery attestor
The ramdisk joins with the discovery token plus the site agent's SignedDiscoveryAssertion that it
served this MAC. The discovery attestor admits it only when all of these hold:
- the token is a live, single-use
discoverytoken for the same site, and itsexpect.macmatches; - the vouching agent is a site agent of that site, holds the live boot lease, and the assertion's epoch is the lease's current epoch;
- the assertion is signed by that agent's key under a
sitecertificate, at most 15 minutes old, and used for one join only; - the ramdisk's claimed MACs include the asserted MAC, and its product UUID matches when asserted.
The result is a certificate valid for at most two hours and restricted to the commissioning command kinds. When the assertion names a running workflow, the ramdisk joins as that workflow's node, so a known machine re-commissions as itself.
Hosts wire the attestors with provision's resolvers:
import { discoveryAttestor, provisionedAttestor } from 'better-compute/pki';
import { discoveryWorkflowNodeResolver, provisionedTargetResolver } from 'better-compute/provision';
export const compute = betterCompute({
// …
attestors: [
discoveryAttestor({ resolveWorkflowNode: discoveryWorkflowNodeResolver() }),
provisionedAttestor({ resolveTarget: provisionedTargetResolver() }),
],
});Both resolvers answer only for workflows that are still running, so a token or assertion from a finished or aborted workflow cannot re-key a node that has moved on. See attestation for the other attestors.
Discovering new machines
Today a machine enters metal by its BMC: metal.enroll with the BMC address, then the inspect.oob
step asks the BMC for the machine's PXE MACs, SMBIOS UUID and IP addresses and records them. That is
what makes the boot entries above possible.
PXE discovery closes the gap for a BMC that cannot name the machine's NICs, such as IPMI. It never enrolls anything: it lets metal learn the PXE MAC of a machine that is already enrolled.
The site agent's side (0056e1e, e763001). A PXE or HTTP-boot DHCP request, or an iPXE script fetch, from a MAC
without a live boot entry, while the agent holds the boot lease, is never answered but listed in
StatusReport.discovered:
| Field | Value |
|---|---|
mac | The machine's MAC |
product_uuid | The SMBIOS UUID from DHCP option 97, the one a BMC also reports |
arch | The client architecture |
first_seen, last_seen, count | When it was first and last seen, and how often |
relay | The DHCP relay (giaddr) it came through |
The list holds at most 256 machines (the oldest last_seen goes first), forgets each a day after it was last seen,
and drops a machine once it gets a boot entry. A new machine asks for a status report at most once every 30 seconds.
Since 0442561 the agent takes only well-formed fields from an unknown client, so none can grow the status report past
the frame limit: a MAC must parse, a UUID is kept only in canonical 36-character form, an arch only as
[a-z0-9_-]{1,32}, and a relay only as an IP address. While the agent runs proxy DHCP, an iPXE script fetch counts
only for a MAC that DHCP already showed, since anyone can fetch a URL.
The control plane's side (3d26428, 8de6e2f). Discovery data is unauthenticated DHCP: any host on the provisioning network can claim any MAC and any UUID. So storing the list binds nothing, and a discovered MAC boots a machine only after an operator confirms it.
- Storing.
metal()declaresmetalDiscoveryStatusHandler()as one of its module status handlers (ComputeModule.statusHandlers, 8de6e2f), andbetter-compute serveand the dev stack run every registered module's handlers after the gateway's XID health handler and before the configuration's ownreports.status. A host that builds its gateway withcreateGatewayitself adds it toreports.status. It stores lists from live site agents only (other nodes' roles are cached per process for 10 minutes, so a host's reports cost no query), inmetal_discovered(migrationmetal/0007_discovered), each agent's list replaced whole and written only when its digest changes (metal_discovery_reports). - Reading.
metal.discovered({ tenantId, siteId }, decided ascompute:sites:readon the site) lists the machines seen in the last 24 hours, merged over the site's agents, newest first, at most 256:mac,productUuid,arch,firstSeen,lastSeen,count(summed over agents),relays,agentNodeIds,nodeIdwhen an enrolled machine has that MAC, andcandidateForwhen it is a machine's candidate awaiting confirmation. Only the tenant that owns the site sees it; any other tenant getsNOT_FOUND, since the list describes the site's network. - Matching, only right after metal's own power cycle. Only
metal.ensureRamdiskmatches, for a machine enrolled with a usable product UUID and no MACs, right after it power-cycled the machine into PXE with its BMC. A MAC becomes the machine's candidate when all of these hold: it was first seen within 10 minutes after that power command was sent (with 30 seconds of clock slack before it); it is the only MAC the UUID was seen from in the last 24 hours, in any of three spellings (as given, with the first three fields byte-swapped as SMBIOS stores them, or fully reversed as IPMI's Get System GUID prints it); no other machine of the site shares the UUID; and no enrolled machine has the MAC. Firmware placeholder UUIDs (all zeros, all ones,03000200-0400-0500-0006-000700080009and00020003-0004-0005-0006-000700080009) never match. A new candidate publishesnode.pxe-mac.discovered(nodeId,mac,productUuid,siteId,agentNodeId,bound), and the machine's metal view shows it asdiscoveredMac. - Confirming. The candidate gets no boot entry and no discovery token until an operator binds it with
metal.confirmMac({ tenantId, nodeId, mac }, decided ascompute:nodes:provisionon the node), which takes the candidate or any MAC the operator knows to be the machine's. It publishesnode.pxe-mac.confirmed(nodeId,mac,discovered,requestId) for the audit trail, answersINVALID_STATEfor a node that already has MACs or is retired andCONFLICTfor a MAC another machine of the site has, and wakes the reconciler, so the waitingmetal.ensureRamdiskgoes on from that MAC. While it waits, the step reports why (waiting for metal.confirmMac, or the reason there is no candidate:not-seen,ambiguous,shared-uuid,mac-enrolled).
The metal view records where a machine's MACs came from as macSource (operator for enroll and metal.confirmMac,
inspection, or discovered; migration metal/0008_mac_source). From the CLI (002dd95):
better-compute metal discovered --site site_01k5w… --format table
better-compute metal confirm-mac node_01k5w… --mac 3c:ec:ef:12:34:56| Command | Flags | Calls |
|---|---|---|
metal discovered | --site ID (required), --tenant | metal.discovered: what the site's agents saw PXE or HTTP boot from MACs with no boot entry, with the machine each is a candidate for; nothing in it is trusted or bound |
metal confirm-mac NODE | --mac MAC (required, aa:bb:cc:dd:ee:ff; - also separates), --tenant | metal.confirmMac: the operator's decision that --mac is the machine's PXE MAC, usually the candidate metal discovered shows; a malformed MAC is a usage error before anything is sent |
In the console, the PXE discovery page (/discovery, 15c11ee) shows the same list for a site you pick, with a
Confirm button on each candidate and a form to bind a MAC by hand; both ask in a browser confirmation before
calling metal.confirmMac, so nothing is bound without the operator's click. See
the console. See IPMI
for the enrollment that uses this.
The discovery attestor also supports operator approval:
approval: 'never'(the default) admits as described above;approval: 'unknown-machines'defers a join that no running workflow names;approval: 'always'defers every discovery join.
A deferred join becomes a pending join request (24 hours by default) that an operator decides with
joinRequests.approve or joinRequests.reject; the
ramdisk retries every 30 seconds with the same CSR and consumes the approval once.
Next
- Provisioning workflows: what runs on the site agent and when.
- BMC drivers and credentials: the BMC side of the site agent.
- PKI: the node CA and JoinService keys the agents join against.